FCS2,FCS3活细胞培养和灌流系统

型号:Bioptechs FCS2,FCS3

价格:请致电:010-67529703

品牌:bioptechs

Bioptechs 细胞微环境控制和培养设备

FCS3活细胞培养和灌流系统

仪器简介

Bioptechs FCS3适用于正置显微镜,是一款用户活细胞培养和观察的封闭系统。FCS3创造性的将高速层流、灌流、高精度的温度控制和高分辨成像能力融为一体,是世界上精密的温度和流体控制活细胞培养系统。 

FCS3系统具有以下点:

1. 简单易用。

2. 可用于低温试验。

3. 与锁有主流显微镜兼容。

4. j确控制细胞培养腔室体积。

5. j确控制腔室的光学性质。

6. j确控制腔室中层流的形状和流速。

7. j确控制腔室的温度和j高的温度均一性。

8. 学术界公认的温度控制和细胞培养能力。

 

系统组成

工作原理

细胞生长在40毫米玻璃盖玻片上。盖玻片上是可灌流培养液的观察腔。培养液从观察腔一侧的端口进入,并从另外一侧流出。培养液在腔体内的流体性质随着观察腔中使用的垫圈形状而发生变化。温度控制通过腔体上面的加热金属框架和腔体下层的加热玻璃实现。该技术提供了整个腔体均匀的温度控制,避免温度梯度的产生,并能对灌流的培养液带来的温度波动进行很好的平衡。

通过使用不同几何形状的下垫圈,可控制层流的流速和形状,研究不同的流体性质对细胞的影响。Bioptechs提供常见几何形状的下垫圈,并提供其它的定制化服务。

FCS2 Starter Set2

The FCS2® System is a closed system, parallel plate flow cell environmental chamber used on a microscope to enable the acquisition of high resolution, time-lapse images of cells undergoing either natural growth or fluidic exposure to variant factors.  The FCS2® System is designed to be used on any inverted microscope as the FCS3® System is specifically for upright microscopes.  Both systems enable the user to define precise and unlimited flow characteristics within the chamber to suit their protocols.  Bioptechs’ patented thermal design provides uniform temperature control across the entire field.  This is a feature that is not possible with a peripheral only heated chambers.

What is it?
The Focht Chamber System 2 (FCS2®) is a closed system, live-cell micro-observation chamber that utilized several patented technologies that offer several exclusive advantages over other chambers. In addition to its uniform temperature control and user definable perfusion capability, it is fully compatible with all modes of microscopy. It is also the only chamber to combine high-volume laminar flow perfusion rates with Koehler illumination and precise temperature control without the need for an air curtain. This is accomplished by the development of micro aqueduct perfusion. A method of introducing media into a fluid optical cavity where the separation of optical surfaces and flow geometry is definable by the user. Therefore, the chamber is adaptable to the protocol instead of having to adapt the protocol to the chamber.

The FCS2 is a flow cell or flow chamber that is designed specifically for the demands of today’s live-cell imaging requirements. It has limitless flow characteristics because its flow geometry can easily be customized by the user. It provides the ability to configure the optical cavity to produce control shear forces, flow characteristics, high or low volume exchange rates, near laminar flow, and anything in between. The most important feature of the FCS2, other than unequalled temperature uniformity, is that the is flow of media is constrained to a precise location over the cells. Open dish type chambers do not provide the flow capabilities of the FCS2. The FCS2 provides unmatched, uniform temperature control, in a user configurable, perfusable, optical imaging cavity.FCS2 users enjoy the following characteristics:

  • Easy no tools needed assembly
  • Compatibility with all modes of microscopy
  • Complete control of the volume within the optical cavity
  • Complete control of the separation between optical surfaces
  • Complete control of the shape or profile of the flow channel
  • Complete control of the temperature uniformly across the entire field
  • Compatible with inverted microscopes


How does it work?
Cells are grown on a 40mm glass coverslip. This coverslip is then incorporated into a perfusable fluid optical cavity that is compatible with all modes of microscopy, and its geometry can be easily defined by the user. This optical cavity is secured into a fixture on the stage of the microscope where it can be perfused with media or remain static. Media that comes into one of the ports on the side of the chamber, emerges in a fluid optical path where the media is precisely directed over the cells. The media is collected within the optical cavity and directed out of the chamber on the other side. The flow characteristics of the media while in the optical cavity are easily modified by selecting gaskets of varying geometry that direct the flow. Temperature control is maintained by both peripheral thermal support from the chamber’s metal frame and heat that is emitted from an electrically conductive optically transparent coating on the “window” of the optical cavity. This technique provides uniform temperature control across the entire field, thus eliminating the temperature gradient that occurs with other designs. This technique also enables the FCS2 to recover from perfusion induced temperature fluctuations in just seconds.

Temperature Control:
The FCS2 was designed to maintain accurate thermal control and allow high-volume laminar flow perfusion. Both of these functions are incorporated into our patented Microaqueduct Slide (see drawing below). The surface of the slide, opposite the specimen side, is coated with an electrically conductive transparent thin film of Indium-Tin Oxide (ITO) and two electrical contacts (busbars). When the FCS2 is completely assembled two electrical contacts, (not shown in drawing), which are contained in the electrical enclosure rest on the busbars. A temperature controller is used to pass a regulated current flow through the ITO Coating. This causes the surface of the slide to heat. The heat is transferred through the perfusable media to the cell surface on the coverslip thereby providing first surface thermal control. The self-locking base of the chamber is also temperature regulated to provide peripheral heat as well.

Thermographic Images:

vislightfcs2
fcs237deg


The thermograph above demonstrates the uniform temperature distribution of an FCS3. Notice that the coverslip temperature is so uniform that its location, in infrared, is indistinguishable from the base of the chamber. This demonstrates the effectiveness of the ITO heated Microaqueduct Slide. It is capable of re-equilibrating cell temperature within seconds of perfusion and eliminates the typical thermal gradient that occurs with peripheral heating.

Microaqueduct Perfusion:
A fluid pathway is formed by separating the Microaqueduct Slide from the coverslip containing cells with a single silicone gasket. This gasket can be any thickness from 50 micron to 1mm and any lateral geometry you choose or create. This arrangement allows the user to define the flow characteristics. Therefore, you are not limited by the geometry of the optical cavity. Instead you select or create it! Fluid access to this flow channel is made through two 14-gauge needle stock tubes protruding from the sides of the chamber top. These tubes provide fluid connection to two perfusion holes in the Microaqueduct Slide that interface two “T” shaped grooves cut into the inner surface of the Microaqueduct Slide. The “T” groove allows the media to seek the path of least resistance and become nearly laminar before flowing across the cells. This technique eliminates the need for the metal perfusion ring and additional gaskets, which are the limiting factors, required by most conventional chambers. (see drawing below)

microaquflo microaqfcs2


Isometric View of Optical Cavity
Microaqueduct Slide is transparent glass but rendered as a solid to improve contrast to illustrate function. Microaqueduct design enables proper Koehler illumination with high-numeric aperture optics for both transmitted and reflected modes of microscopy. Suitable for static or high rate of flow procedures where a rapid exchange of media is required with low cell surface shear Cell temperature can be controlled from ambient to 50 degrees C +/- 0.2 degrees C without the need of an air curtain. Temperature is controlled uniformly across entire field with media equilibrating as it enters the chamber. (see drawing above)

FCS2 Chamber Features
  • Closed system so that bicarbonate CO2 or organic buffers can be employed
  • Compatible with 1/16″ tubing for perfusion (C-Flex, Tygon, etc.)
  • Easily assembled with ordinary skill (no tools required)
  • Stand-alone temperature controller with an alarm circuit to safeguard your cells
  • Near laminar flow


Exploded View of FCS2 Chamber
fcs2_explode

  1. Electrical Enclosure
    Can also be detached to sterilize the perfusion tubes
    Temperature sensor
    Heater contacts
  2. Upper Half (Top)
    Contains the perfusion tubes
  3. Perfusion Tubes (14 gauge) (CO2 Perfusion Drawing)
  4. Upper Gasket
  5. Microaqueduct Slide
    An optical surface which integrates perfusion and temperature control
    High-volume laminar flow
    Koehler Illumination
    Electronically conductive coating for temperature control
  6. Singular lower gasket
    This gasket can have any internal geometry you desire
    Standard thicknesses from .1mm to 1mm
    Allows you to define the volume and flow characteristics of the chamber
  7. 40mm coverslip
    Surface where your cells are grown
  8. Self locking base
    Designed to assure parallel uniform closure, eliminate leaks, & broken coverslips
    Temperature controlled
    Dovetail mounted to scope for stability
    No tools for assembly

Items 5,6 & 7 are the optical cavity, the gasket (#6) can be changed to any one of the gaskets below or a custom gasket can be made to make any flow geometry, or media volume you want. The coverslip comes in a standard 0.17mm, #1.5 thickness but is also available in 0.5mm, #5 coverslip.


Singular lower gasket
By simply changing this one gasket you can change the volume of the chamber. This gasket can have any internal geometry you desire and can be any thickness from 0.1mm to 1mm. The drawing below shows the standard shapes of the gaskets that we include with every FCS2. We also include solid gaskets for you to custom fit to your application. Once you have found the shape that works best for your experiment, you can contact us to have a die made to those specifications. Examples of standard gasket outlines (below)

stdgasketset

Standard Gasket Set includes:
(3) 0.1mm Thick 30mm Round
(2) 0.1mm Thick 14 x 24 Rectangle
(3) 0.25mm Thick 30 mm Round
(2) 0.25mm Thick 14 x 24 Rectangle
(1) 0.25mm Thick Blank
(3) 0.5mm Thick 30mm Round
(2) 0.5mm Thick 14 x 24 Rectangle (2) 0.5mm Thick Blank
(5) 0.75mm Thick 30mm Round w/holes
(2) 0.75mm Thick 14 x 24 Rectangle
(1) 0.75mm Thick Blank
(2) 1.0mm Thick 30mm Round
(1) 1.0mm Thick 14 x 24 Rectangle
(1) 1.0mm Thick Blank

To order a specific geometry please see the price list for part numbers and prices. Gaskets are sold 5 gaskets per pack.
In addition to the standard gasket set that comes with the FCS2 Starter Kit, shown above, there are a variety of gasket geometries, and thicknesses ranging from 0.1mm to 1mm available. Custom thicknesses and materials available upon request. See the additional gaskets shapes chart below.
FCS_Gaskets
Custom shapes are available. Simply contact Bioptechs to make arrangements for their production. All dimensions below are in millimeters. Please specify the die number that is located on the gasket drawing below and the thickness of the gasket when ordering.

Perfusion Diagram for FCS2


To assist you and Bioptechs in selecting the most appropriate system to meet your needs, please review and fill out the following questionnaire.
Micro-Environmental System Profile Questions

 

FCS2 Starter Set includes:

  • FCS2 Chamber
  • Controller
  • 5 Micro aqueduct Slides
  • 100 #1.5 – 40mm German Desag263 Coverslips
  • 30 piece Gasket Set

Standard FCS2 Chamber Specifications:

Physical Size 75mm OD 13mm high
Coverslip No. 1.5 thick x 40mm Diameter
Imaging Aperture 22mm
Maximum Volume 706mm^3
Minimum Volume 4mm^3
Maximum Volume Exchange Rate 1/sec
Minimum Fluid Aperture 0.6mm^2
Separation between optical surfaces 50 – 1000 microns
External port ID 1.6mm
Temperature Stability +/- 0.2 degrees C
Standard Temperature Range with use of Electronic Controller Ambient to 55 degrees C

Standard FCS2 Top:


Tube Tube Length (mm) Tube Inside Diameter (mm) Dead Volume (μl)
A 29 1.57 56.14
B 10 0.88 6.08
Total Dead Volume 62.22