Browse All BHQ probes master mix

BHQ® Probe Master Mix is a versatile 2X PCR master mix specially designed to deliver optimal SNP genotyping results for high-throughput, ultra low volume, endpoint probe-based SNP genotyping. BHQ Probe Master Mix frees you to use an extraction method of your choice across a range of probe, sample, and template types. For high-precision genotyping, pair BHQ Probe Master Mix with BHQ or BHQplus® probes for a high-fidelity, low background SNP genotyping assay that yields clear results minus the challenges associated with ambiguous data interpretation.

Filter Product List:
Catalog # Item Name Price Size/Scale Note QTY ADD Conjugation Ratio

${{item.salePrice}} ${{item.userPriceBook.salePrice}} ${{item.unitPrice}} ${{item.userPriceBook.unitPrice}} TBD {{item.sizeAndScale}} {{item.message}}

If ordering ValuMix Assay for SNP Genotyping, which BHQ Probe Master Mix kit volume should I order?

ValuMix Assays are optimized to deliver the optimal probe/primer ratio for a final primer/probe concentration of 200 µM in a single tube. All ValuMix Assays contain 2 x BHQplus probes, one with a FAM labeled 5' end and another with a dye of your choice TET, CAL Fluor® Gold 540, CAL Fluor Orange 560.

All ValuMix probes are reverse-phase HPLC (RP HPLC) purified and combined with salt-free primers.

ValuMix for SNP genotyping (probe concentration) ValuMix Catalog Number(s) BHQ Probe Master Mix minimum kit volume BHQ Probe Master Mix Catalog Number(s)
2 nmol FTBP-2 (FAM/TET)
FCBP-2 (FAM/CAL Fluor Orange 560))
FGBP-2 (FAM/CAL Fluor Gold 540)
5 mL KBS-1040-003 No ROX
KBS-1040-013 Low ROX
KBS-1040-023 Standard ROX
5 nmol FTBP-5 (FAM/TET)
FCBP-5 (FAM/CAL Fluor Orange 560)
FGBP-5 (FAM/CAL Fluor Gold 540)
25 mL KBS-1040-005 No ROX
KBS-1040-015 Low ROX
KBS-1040-025 Standard ROX
12 nmol FTBP-12 (FAM/TET)
FCBP-12 (CAL Fluor Orange 560)
FGBP-12 (CAL Fluor Gold 540)
200 mL KBS-1040-006 No ROX
KBD-1040-016 Low ROX
KBS-1040-026 Standard ROX

Ready to purchase BHQ Probes Master Mix? Choose from the options below. 

Catalog Number Description Size Order
KBS-1040-001 2X BHQ Probe Master Mix, No ROX 1.25 mL Order Now
KBS-1040-002 2X BHQ Probe Master Mix, No ROX 2.5 mL Inquire
KBS-1040-003 2X BHQ Probe Master Mix, No ROX 5 mL Order Now
KBS-1040-004 2X BHQ Probe Master Mix, No ROX 10 mL Inquire
KBS-1040-005 2X BHQ Probe Master Mix, No ROX 25 mL Inquire
KBS-1040-006 2X BHQ Probe Master Mix, No ROX 200 mL Inquire
KBS-1040-011 2X BHQ Probe Master Mix, Low ROX 1.25 mL Order Now
KBS-1040-012 2X BHQ Probe Master Mix, Low ROX 2.5 mL Inquire
KBS-1040-013 2X BHQ Probe Master Mix, Low ROX 5 mL Order Now
KBS-1040-014 2X BHQ Probe Master Mix, Low ROX 10 mL Inquire
KBS-1040-015 2X BHQ Probe Master Mix, Low ROX 25 mL Inquire
KBS-1040-016 2X BHQ Probe Master Mix, Low ROX 200 mL Inquire
KBS-1040-021 2X BHQ Probe Master Mix, Standard ROX 1.25 mL Order Now
KBS-1040-022 2X BHQ Probe Master Mix, Standard ROX 2.5 mL Inquire
KBS-1040-023 2X BHQ Probe Master Mix, Standard ROX 5 mL Order Now
KBS-1040-024 2X BHQ Probe Master Mix, Standard ROX 10 mL Inquire
KBS-1040-025 2X BHQ Probe Master Mix, Standard ROX 25 mL Order Now
KBS-1040-026 2X BHQ Probe Mastermix, Standard ROX 200 mL Inquire

BHQ Probe Master Mix

BHQ Probe Master Mix SNP clusters

Competing master mix

Competing master mix

Figure 1: A direct comparison of BHQ Probe Master Mix to that of a leading market competitor on crudely extracted and challenging sunflower seed samples known to contain inhibitors. BHQ Probe Master Mix shows tight and easily resolvable clusters with limited no template control (NTC) movement even in the presence of sample inhibitors present in higher concentrations due to the very low total reaction volume of 0.8 渭L. Competing mix shows incomplete amplification due to inhibitors resulting in samples where genotype cannot be assigned (pink circles). Experiments adhered to respective mix protocols on hot shot extracted sunflower seed samples using BHQplus Probes on a Nexar Integrated Liquid Handling and Assay Processing System.

Storage and Handling

BHQ Probe Master Mix is stable for up to one week at 4 °C, 1-year at -20 °C.

Instrument Compatibility

Nexar Inline Liquid Handling and Assay Processing System
IntelliQube®
SNPline™ workflow of modular laboratory instrumentation, which includes the Hydrocycler

Other Platforms

Any appropriate qPCR instrument of FRET- capable plate reader

Related Links

How many 10 µL reactions can I get with each kit?

Kit 10 µL Reactions
1.25 mL 250
2.5 mL 500
5 mL 1000
10 mL 2000
25 mL 5000